DOSING
LABELLING
PLUS/MINUS CONTROL
PERCENT WEIGHING
TOTALIZING
PARTS COUNTING
PEAK HOLD
FORMULATION
STATISTICS
CHECKWEIGHING
GLP PROCEDURES
ANIMAL WEIGHING
DIFFERENTIAL WEIGHING
Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
REPLACEABLE UNIT
STATISTICAL QUALITY CONTROL
ALIBI MEMORY
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
TRANSACTIONS
DATASHEET
Maximum quantity of verification units | 6000 e |
OIML Class | II or III |
Display | 10.1” graphic colour touchscreen |
Protection class | IP 68 (1h max)/69 |
Communication interface | 2×RS232, 2×USB, Ethernet, 4 IN / 4 OUT (digital) |
Wi-Fi® module (option) | 802.11 b/g/n |
Profibus module (option) | DP SLAVE |
PROFINET module (option) | 1 × RJ45 |
Analog output module (option) | 4-20mA, 0-20mA, 0-10V |
Inputs/Outputs (option) | 12IN / 12OUT (IN – 5-24 VDC, OUT – max 30 VDC, 0.5 ADC) |
Maximum increase of signal | 19.5 mV |
Minimum volatge per verification unit | 0.4 µV |
Maximum voltage per verification unit | 3.25 µV |
Minimum load cell impedance | 50 Ω |
Maximum load cell impedance | 1200 Ω |
Load cell excitation voltage | 5V DC |
Connection of load cells | 4 or 6 wires + shield |
Operating temperature | -10 ÷ +40°C |
Relative humidity | 10% ÷ 85% RH no condensation |
Touch panel | capacitive |
Keypad | panel touchscreen |
Housing | stainless steel |
Operating system | Linux |
Processor | quad-core 64-bit Cortex-A53 1.2 GHz |
Memory | RAM 1GB LPDDR2 |
Data memory | 16 GB (micro SD) |
Max number of platforms | 4 (2 × internal weighing module + 2 × external weighing modules) |
COMPATIBLE WITH
- HRP Platforms High Capacity
- Stainless steel HRP. H Platforms
- Platforms in plastic casing
- Mild steel powder coated weighing platforms
- Waterproof stainless steel platforms
- Stainless steel ramp platforms with LD lifting system
- Stainless steel platforms, pit version
- Ramp stainless steel platforms
- Audit Trail Reader
- E2R System
- Label Editor R02
- Parameter Editor
- Scales Editor 2.0
- R. Barcode
- R-LAB
- RAD-KEY
- RADWAG Connect
- RADWAG Development Studio
- RADWAG Remote Desktop
- LabVIEW Driver
- Moxa Uport 1110 Converter
- RS 232, RS485 cables
- RS232 cables (scale-Ethernet)
ADDITIONAL MODULES
The Audit Trail Reader freeware enables to acquire data from the weighing instrument and export it as files to pdf, xls, csv, html formats.